Q340A thermocouples sense the pilot flame on gas-fired heating systems. The pilot flame heats the tip of the thermocouple, producing a temperature differential between it and the base to generate a small amount of DC power, measured in millivolts.
Features
- Push-in clip, split nut, and adapter assembly for easy pilot burner installation.
- Spade or quick-connect terminals available for millivolt gas control connections.
- Male nut connector for Pilotstat safety control power units.
- Available in a variety of lead lengths.
Product Specifications
- Application Thermocouple
- Includes Adapter and Push In Clip
- Tradeline Value Super Tradeline
- Temperature Ratings (C) Hot Junction--760 C; Cold Junction--416 C
- Temperature Ratings (F) Hot Junction--1400 F; Cold Junction--780 F
- Voltage 30 mV; Open circuit output--26 mV to 32 mV
- Connection Type Push-in Clip,11/32 32 Male Connector Nut
- Resistance 0.02 ohms
- Length (in.) 24 in.
- Length (mm) 610 mm